DA180 series basic AC servo drive Function codes
-100-
This parameter specifies the DEC time for quick stop. It indicates the time taken to decelerate from
100% of the rated speed to 0.
Absolute encoder work
mode
This parameter specifies the running mode of the multiturn absolute encoder. Though the encoder
working with the motor is a multiturn absolute encoder, it is still considered as a single-turn
encoder by default. If the multiturn absolute function is needed, you need to prepare the spare
battery for the encoder and set the work mode as the multiturn absolute mode.
Clear absolute encoder
multiturn
This parameter specifies whether to clear the multiturn data for the multiturn absolute encoder. If
this function is enabled, the multiturn data is cleared while the single-turn data remains
unchanged, but the absolute position in the feedback is cleared.
Note: If you use a multiturn absolute encoder, after machinery installation, you can clear the absolute
encoder after detecting the absolute zero position of the mechanic system at first power-on.