DA180 series basic AC servo drive Function codes
-131-
P3.24
Filter of AI 2
Setting range
Default
Unit
Applicable
mode
0.01000.0
1.0
ms
P
S
T
This parameter specifies the time constant of the first-order low-pass filter corresponding to analog
input 2. Setting this parameter can smooth the command change when the analog input changes
sharply.
See the following figure:
Command before filtering
Input 2
Time
Command after filtering
Command after filtering
P3.24P3.24
Vc
0.632Vc
0.368Vc
P3.24
Data size
16bit
Data format
DEC
Modbus address
1648, 1649
CANopen address
0x2318, 0x00
P3.25
OV protection threshold
of AI 2
Setting range
Default
Unit
Applicable
mode
0.00010.000
0.000
V
P
S
T
This parameter specifies the OV protection value of analog input 2.
Note:
The default value 0 indicates OV protection is not used.
The setting of this parameter cannot be greater than 10V. Otherwise, the drive may be
damaged.
P3.25
Data size
32bit
Data format
DEC
Modbus address
1650, 1651
CANopen address
0x2319, 0x00
P3.26
1
Function of AI 1
Setting
range
Default
Unit
Applicable
mode
07
0
-
P
S
T
P3.27
1
Function of AI 2
Setting
range
Default
Unit
Applicable
mode
07
3
-
P
S
T