DA180 series basic AC servo drive Function codes
-137-
P3.51
Output mode of
position arrival
Setting range
Default
Unit
Applicable
mode
04
0
-
P
This parameter specifies the output condition and subsequent action of position arrival.
Setting
Meaning
[0]
The output is valid when the position deviation is in the range of P3.50.
1
The output is valid when there is no position command and the position deviation
is in the range of P3.50.
2
The output is valid when there is no position command, the zero-speed detection
signal is valid, and the position deviation is in the range of P3.50.
3
The output is valid when there is a transition from with a position command to
without a position command and the position deviation is in the range of P3.50.
Subsequently, the system continuously outputs the valid state within the time
specified by P3.52. Then, the system updates the output status of position arrival
based on the position command and position deviation.
4
The output is valid when there is a transition from with a position command to
without a position command and the position deviation is in the range of P3.50.
Subsequently, the system continuously outputs the valid state within the time
specified by P3.52.
P3.51
Data size
16bit
Data format
DEC
Modbus address
1702, 1703
CANopen address
0x2333, 0x00
P3.52
Hold time of position
arrival output
terminal
Setting range
Default
Unit
Applicable
mode
030000
0
ms
P
This parameter specifies the hold time of the position arrival output terminal.
Setting
Meaning
[0]
The hold time is infinite, and the holding is valid until the position in
a next position command is arrived at.
130000
The holding is valid within the setting range. It becomes invalid
once a next position command is received.
P3.52
Data size
16bit
Data format
DEC
Modbus address
1704, 1705
CANopen address
0x2334, 0x00
P3.53
Speed consistency
threshold
Setting range
Default
Unit
Applicable
mode
1020000
50
r/min
P
S
T
This parameter specifies the condition for detecting speed consistency.
If the difference between the speed command and motor speed is less than the setting of this
parameter, then the speed consistency output status is valid.

Table of Contents

Related product manuals