DA180 series basic AC servo drive Function codes
-138-
If the detection finds there is a lag of 10 r/min, the actual speed consistency range is as follows:
If the speed consistency output is invalid, the validity threshold is (P3.53 – 10) r/min.
If the speed consistency output is valid, the invalidity threshold is (P3.53 + 10) r/min.
This parameter specifies the condition for detecting speed reaching output. If the transient motor
speed [R0.21] exceeds the setting of this parameter, the output is valid. The detection finds a lag
of 10 r/min.
This parameter specifies the condition for detecting zero speed output. When the absolute value of
the motor speed is within this range, the speed is considered as zero speed and the zero speed
output signal is valid. The detection finds a lag of 10 r/min.
Servo lock time after
braking
This parameter specifies the locked time of the servo after braking in locked state. If the servo is
off in locked state, the digital output of the electromagnetic brake release signal (0x005 or 0x105)
is invalid. Then the servo keeps being locked for a period of time so that the motor does not rotate
during the action of the relay.