EasyManua.ls Logo

INVT DA180-S2R8SG0

INVT DA180-S2R8SG0
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA180 series basic AC servo drive Appendix
-275-
Function
code
Parameter
Unit
Setting range
Default
Applicable
mode
P0.43
Reverse of AI 1
-
01
0
PST
P0.45
Dead zone of AI 1
V
0.0003.000
0.000
PST
P0.46
Internal speed 1/speed
limit 1
r/min
-2000020000
100
ST
P0.47
Internal speed 2/speed
limit 2
r/min
-2000020000
0
ST
P0.48
Internal speed 3/speed
limit 3
r/min
-2000020000
0
ST
P0.49
Internal speed 4/speed
limit 4
r/min
-2000020000
0
ST
P0.50
Internal speed 5
r/min
-2000020000
0
S
P0.51
Internal speed 6
r/min
-2000020000
0
S
P0.52
Internal speed 7
r/min
-2000020000
0
S
P0.53
Internal speed 8
r/min
-2000020000
0
S
P0.54
ACC time
ms
030000
0
S
P0.55
DEC time
ms
030000
0
S
P0.56
S-curve ACC time
ms
01000
0
S
P0.57
S-curve DEC time
ms
01000
0
S
P0.58
Zero speed clamp mode
-
03
0
ST
P0.59
Zero speed clamp speed
threshold
r/min
1020000
30
S
P0.60
Torque command source
-
03
1
T
P0.61
Torque command direction
setting
-
01
0
T
P0.62
Gain of AI 2
[P3.27 unit]/V
02000
100
PST
P0.63
Reverse of AI 2
-
01
0
PST
P0.65
Dead zone of AI 2
V
0.0003.000
0.000
PST
P0.66
Internal torque command
%
-500.0500.0
0.0
T
P0.67
Speed limit mode
-
01
0
T
P0.68
Torque command ramp
time
ms
010000
0
T
P0.69
DEC time for quick stop
ms
010000
500
PST
P0.70
1
Absolute encoder work
mode
-
01
0
PST
P0.71*
Clear absolute encoder
multiturn
-
01
0
PST

Table of Contents