DA180 series basic AC servo drive Function codes
-149-
P4.34
1
Brake OL protection
Setting range
Default
Unit
Applicable
mode
02
0
-
P
S
T
This parameter specifies the regenerative brake mounting mode and overload protection mode.
Setting
Meaning
[0]
Regenerative brake disabled
1
Regenerative brake built in
2
Regenerative brake externally connected
P4.34
1
Data size
16bit
Data format
DEC
Modbus address
1868, 1869
CANopen address
0x2422, 0x00
P4.35
Enabling motor
runaway detection
Setting range
Default
Unit
Applicable
mode
01
1
-
P
S
T
This parameter specifies whether to enable the motor runaway detection function.
Setting
Meaning
0
Disable
[1]
Enable
P4.35
Data size
16bit
Data format
DEC
Modbus address
1870, 1871
CANopen address
0x2423, 0x00
P4.36
1
Main-power UV
protection
Setting range
Default
Unit
Applicable
mode
01
1
-
P
S
T
This parameter specifies whether the drive reports a main circuit undervoltage alarm when the
main power encounters a main circuit undervoltage fault.
Setting
Meaning
0
In servo enabling state, the drive does not report the fault Er13-1 when
main circuit undervoltage occurs.
[1]
In servo enabling state, the drive reports the fault Er13-1 and stops
when main circuit undervoltage occurs.
P4.36
1
Data size
16bit
Data format
DEC
Modbus address
1872, 1873
CANopen address
0x2424, 0x00
P4.37
Main-power UV
detection time
Setting range
Default
Unit
Applicable
mode
702000
70
ms
P
S
T
This parameter specifies the time taken to detect main power undervoltage.
Note: The value 0 indicates the function of detecting main power undervoltage is invalid.