20
Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
3. Get to know Inxpect SRE 200 Series
Part Description C201B-P C201B-F C202B C203B
M2 Status LED of hardware functions of
the primary micro-controller:
l
off: normal behavior
l
steady red: contact
Technical Support
x x x x
N Fieldbus port no.1 with LEDs
(PROFIsafe or EtherCAT® IN)
x x - -
O Fieldbus port no.1 with LEDs
(PROFIsafe or EtherCAT® OUT)
x x
- -
Note: only for C201B-F: the processing direction is from the N connection to the O connection. In normal
operation, the device receives the data from the controller on N and sends the outgoing data on O.
3.2.6 System status LEDs
The LEDs are each dedicated to a sensor, and can display the following statuses:
Status Meaning
Steady green Normal sensor function and no motion detected
Orange Normal sensor function and some motion detected
Flashing red Sensor in error (see "Control unit LED" on page85)
Steady red System error (see "Control unit LED" on page85)
Flashing green Sensor in boot status (see "Control unit LED" on page85)
3.2.7 PROFIsafe Fieldbus status LEDs
The LEDs reflect the status of the PROFIsafe Fieldbus, and their meanings are reported below.
Note: F1 is the LEDat the top, F6 is the LED at the bottom.
LED Status Meaning
F1 (power) Steady green Normal behavior
Flashing green or
off
Contact Technical Support
F2 (boot) Off Normal behavior
Steady or flashing
yellow
Contact Technical Support
F3 (link) Off Data exchange is running with the host
Flashing red No data exchange
Steady red No physical link
F4 (not used) - -
F5 (diagnosis) Off Normal behavior
Flashing red DCP signal service is initiated via the bus
Steady red diagnostic error at PROFIsafe layer (wrong F Dest Address, watchdog
timeout, wrong CRC) or diagnostic error at PROFINET layer (watchdog
timeout; channel, generic or extended diagnosis present; system
error)
F6 (not used) - -
3.2.8 FSoE Fieldbus status LEDs
The LEDs reflect the status of the FSoE Fieldbus as described below.
Note: F1 is the LEDat the top, F6 is the LED at the bottom.