8
Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
1. This manual
1.1.4 Instruction manual updates
Publication
date
Code Hardware version Firmware version Updates
DEC 2023 Inxpect SAF-IM-200S_
5m_7_00047_en_v1.5
Control units:
l
Type A: 2.2
l
Type B: 2.4
Sensors:
l
S201A model:
2.2
l
S203A model :
1.0
Control units:
l
Type A: 2.0
l
Type B: 2.0
Sensors:
l
S201A: 3.2
l
S201A-W: 5.0
l
S203A-W: 5.0
Changed the total maximum length of the CAN bus
line into 80 m (262.5 ft).
Changed control unit maximum power into 11.2 W.
Changed values for Case 4 in "Dynamic configuration
through the digital inputs" on page35.
MAY 2023 Inxpect SAF-IM-200S_
5m_7_00047_en_v1.4
Control units:
l
Type A: 2.2
l
Type B: 2.4
Sensors:
l
S201A model:
2.2
l
S203A model :
1.0
Control units:
l
Type A: 2.0
l
Type B: 2.0
Sensors:
l
S201A: 3.2
l
S201A-W: 5.0
l
S203A-W: 5.0
Added control units: C201A-F, C201B-P, C201B-F,
C202B, C203B.
Added sensors: S201A-W, S201A-WL, S203A-W,
S203A-WL.
Updated procedures in "Validate the safety func-
tions" on page77.
Added sensor configuration error details ("Sensor
configuration error (SENSOR CONFIGURATION
ERROR)" on page97.
Added multi-user management for the Inxpect
Safety application.
Changed name of digital input function: Activate
dynamic configuration > Dynamic configuration
switch
New input functions: Restart signal on a single chan-
nel (cat 2), System recondition on a single channel
(cat.2), and Fieldbus controlled on a single channel
(cat.2).
New inputs options: Redundancy mode, Encoded
channel.
New output functions: Detection signal group, Field-
bus controlled on a single channel.
Updated Factory reset procedure ("Restore factory
default settings" on page82).
Added Electromagnetic robustness parameter ("Elec-
tromagnetic Robustness" on page52).
Added Static object detection sensitivity.
Updated "Dangerous area calculation" on page58.
Added "OSSD diagnostic checks" on page25.
Other minor changes.
APR 2022 SAF-UM-SBVBus-en-
v1.3
l
C201A-PNS,
C202A and
C203A: 2.1
l
S201A: 2.1
l
S201A-MLR:
2.1
l
C201A-PNS,
C202A and
C203A: 1.6.0
l
S201A: 3.1
l
S201A-MLR:
3.1M
Changed system, control unit, and sensors denom-
ination.
Renamed safety working modes ("Always restart pre-
vention" > "Always-on restart prevention"; "Always
access detection" > "Always-on access detection").
Added S201A-MLR sensor.
Updated standard list in "Standards and Directives"
on page13.
Updated the anti-rotation around axes function (dis-
abled by default, can be enabled for each axis of
each sensor) in "Anti-tampering functions:anti-rota-
tion around axes" on page49.
Updated the anti-masking function (can be disabled
for each axis of each sensor) in "Anti-tampering
functions:anti-masking" on page50.
Updated parameters list and organization in "Con-
figuration application parameters" on page118.
Updated K value in "Formula for stationary applic-
ation" on page58.
Minor changes.
Note: the firmware of the control unit can be updated through the Inxpect Safety application. The latest firmware
version available contains the features described in the manual at the system level. The sensor firmware cannot be
updated.