86
Inxpect SRE 200 Series| Instruction manual v1.5 DEC 2023 |Inxpect SAF-IM-200S_5m_7_00047_en_v1.5|© 2021-2023 Inxpect SpA
9. Troubleshooting
LED Status
Inxpect Safety
application messages
Problem Solution
S4 Steady red PERIPHERAL ERROR At least one of the
control unit
peripherals is in
error
Check the status of the
terminal block and
connections.
If the problem persists,
please contact Technical
Support.
S5 Steady red CANERROR Communication
error with at least
one sensor
Check connections of all
sensors in the chain starting
from the last sensor in error.
Check that all the sensors
have an assigned ID (in
Inxpect Safety Settings >
Node IDAssignment).
Check that the firmware of
the control unit and sensors
are updated to the
compatible versions.
S6 Steady red FEE ERROR, FLASH
ERROR or RAM ERROR
Configuration saving
error, configuration
not performed or
memory error
Reconfigure or configure the
system (see "Manage the
configuration" on page81).
If the error persists, please
contact Technical Support.
All LEDs from
S1 to S6
together
Steady red FIELDBUS ERROR Communication
error on the Fieldbus
At least one input or output
is configured as Fieldbus
controlled.
Check that the cable is
correctly connected,
communication with the
host is correctly established,
watchdog timeout is
configured correctly, and
exchanged data are not
maintained passivated.
All LEDs from
S1 to S5
together
Steady red DYNAMIC
CONFIGURATION ERROR
Error in the selection
of the dynamic
configuration: invalid
ID
Check the preset
configurations within the
Inxpect Safety application.
All LEDs from
S1 to S4
together
Steady red SENSOR
CONFIGURATIONERROR
Error during the
configuration of the
sensors
Check the sensors
connected and try again to
perform the configuration of
the system via the Inxpect
Safety application.
Check that the firmware of
the control unit and sensors
are updated to compatible
versions.
At least one
LED
Flashing red See "Sensor LED" on the
next page
Sensor
corresponding to the
flashing LED in error
** (see"Sensor LED"
on the next page)
Check the problem through
the LED on the sensor.
At least one
LED
Flashing green See "Sensor LED" on the
next page
Sensor
corresponding to the
flashing LED in error
** (see"Sensor LED"
on the next page)
If the issue persists longer
than one minute, please
contact Technical Support.
All LEDs Steady orange - The system is
starting up.
Wait for a few seconds.

Table of Contents