Digital Network Public Address & Voice Alarm System
- 28 -
7. Normal mic/line input, connect user MIC/CD/MP3/TUNER standard audio signal(when input 6.3 plug
unbalance audio signal, which is mic input, when input XLR balance audio signal, which is line input.
8. Device online communication interface.
9. CAN interface, connect to charger(VA-6000BC or DC 24V UPS).
10. Backup power input interface(connect DC 24V which is VA-6000BC power output interface).
11. Rack earth point( Mind: make sure this point can connect with land).
12. Power switcher and main power input with fuse.
5.5.4.Technical Specification
Electrical Specifications
AC
Voltage
~220-240V/50-60Hz
Max current
3A(not including wired 4 output)
Fuse specification
250V/6.3A, slow type
DC
Voltage
24V DC, ±20%
Max current
25A(not including wired 4 output)
Power consumption
600W
Performance index
Line in
Distortion
<1%, 1KHz rate power output
Frequency response
80Hz~20KHz
Sensitivity
350mV
Impedance
10KΩ
Signal to Noise Ratio
>70dB
Emergency microphone
Sensitivity
5mV
Impedance
600Ω
Contact output
8 channel relay programmable output Short circuit, no voltage
Level model
Max 3.3V
Short circuit mode
No voltage, short circuit
Cooling way
wind blow cooling way
Protection way
delay/over heat/short circuit/overload
Mechanical index
Dimension (L*W*D)
484*88*447mm
N/W
About 11.5Kg
Installation
desk surface 19 inch rack
Color
Black
Environment requirement
Operate temperature
+5 ~ +40
Stock temperature
-20 ~ +70
Relative temperature
<95%(No condensation)