Digital Network Public Address & Voice Alarm System
- 36 -
5.8.PA Microphone —VA-6000RM
VA-6000RM can be used in remote control VA-6000 system, can allow user to control system voice
information and zone paging, support 8 zones/group selection, and can extended by MIC(VA-6000EM),
can maxium add 7 keyboard, every extended keyboard can add 8 zones.
5.8.1.Features
1. 1 key zone/group selection, easy to operate.
2. MIC output level is adjustable.
3. Balanced transmission can extend the transmission
distance by CAT-5.
4. Showy system fault and main module indication.
5. Support zone/group selection keyboard extention.
6. Support line audio input and the input volume
adjustment.
7. Paging key mode and PTT mode can be configured.
8. Support line redundant wiring.
9. Support monitor output.
10. Support 24V phantom power.
11. Paging priority is configurable.
5.8.2.Front panel
1. Gooseneck microphone socket.
2. Fault reset/close partition.