Digital Network Public Address & Voice Alarm System
- 31 -
10. Rack earth point (remind: please make sure reliable earth).
11. power switch and main power input socket with fuse.
5.6.4.Technical specifications
Electric index
Alternating current
Voltage
~220-240V/50-60Hz
Maximum current
1.5A
Size of fuse
250V/2A, slow type
DC output
Voltage
24V storage battery
Max current
50A*Each line
Power consumption
2400W
Charging data
Charging max current
10A adjustable
Cooling
Temperature control fan
5.7.Fireman remote MIC—VA-6000FM
VA-6000FM is used for remote control of VA-6000 system, it allow user control system voice information
and zone paging, support 8 zones/group selection, and can extended by MIC extension unit(VA-6000EM),
support max 7 keyboard, every extension keyboard can add 8 zones.
5.7.1.Features
1. 1 key zone/group selection, easy to operate.
2. Mic output level is adjustable.
3. Balanced transmission can extend transmission distance by CAT-5.
4. Showy system failure and main module status indication.
5. Support zone/group selection keyboard extention.
6. Support line audio input and support input volume adjustment.
7. Support line redundancy wiring.