EasyManua.ls Logo

ITW Alpine ALS 4.0 XE - 4.4 Calibrate Bevel Axis (B1)

ITW Alpine ALS 4.0 XE
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
ALS 4.0 XE
PRODUCT MANUAL
EN
Figure 65
Step 7 – Move the breaker switch CB202 to the o
position to disable power to the blade motor (shown in
Figure 66).
Figure 66
Step 8 – Close the electrical control panel.
Step 9Turn on the main power to the ALS 4.0.
Figure 67
Step 10 – Follow the normal startup and homing
procedures (Section 3.1).
Step 11 – In the Manual Control Screen, verify that B1 is
registering “0.0”.
O Position
On Position
4.4 Calibrate Bevel Axis (B1)
Step 1 – Place a magnetic digital angle gauge on the Z1
linear rails, as shown in Figure 63.
Digital
Angle
Gauge
Figure 63
Step 2 – Select the “zero button on the gauge to set the
angle to 0.0.
Step 3 – Once the gauge has been set to 0.0, place it on
the blade as shown in Figure 64.
Figure 64
Step 4 – Close the saw door.
Step 5 – Open the main electrical panel.
Step 6 – Locate the blade breaker CB202 (Figure 65)

Table of Contents