EasyManua.ls Logo

ITW Alpine ALS 4.0 XE - 4.7 Calibrate Centerline (T1)

ITW Alpine ALS 4.0 XE
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
ALS 4.0 XE
PRODUCT MANUAL
EN
4.7 Calibrate Centerline (T1)
Step 1 – Place a 2x4 board (dimensional lumber) across
L1 & L2.
Step 2 – Engage the L1 & L2 Pushers by pressing the
“L1 Pusher In and “L2 Pusher In buttons on the Manual
Control Screen.
Figure 95
Step 3 – Engage the L1 & L2 Clamps by pressing the
“L1 Clamp Down and “L2 Clamp Down buttons on the
Manual Control Screen.
Figure 96
Step 4 – Move T1 to “1.75” using the “Move T1” button
on the Manual Control Screen.
Figure 97
Step 5 – Conrm Z1 is at “0.0”.
Step 6 – If the saw was equipped with a bevel axis,
conrm B1 is at “0.0”.
Step 7 – Move A1 to 45° using the “Move A1” button on
the Manual Control Screen.
Figure 98
Step 8 – Start blade using “Saw Motor On” button on
the Manual Control Screen.
Figure 99
Step 18 – Open the door to the saw cabinet, shut down
the computer, and then disconnect electricity and air
supply.
Step 19 – Lock and tag out the electrical and air supply
in accordance with OSHA procedures (ie. OSHA 29 CFR
1910.147).
Step 20The Figure below shows the bolts that mount
the motor to the angle plate.
If the saw is an “H” model, remove the B-axis cover plate
to access the 4th motor mount bolt.
If the saw is an “HB” model, rotate B1 until the 4th motor
mount bolt is accessible (approximately 35°). It is not
necessary to remove the B-axis cover plate or the B-axis
over-travel stop.
B-axis Cover Plate
B-axis Over-Travel Stop
Set Screws
Motor Mount Bolts
Figure 94
Step 21 – Loosen the bolts and use the set screws to
move the motor one half the amount of the dierence
between the measurement taken and the required
15/32”. Be careful to move the motor in the correct
direction. With A1 at 90°, move the motor right if the
Center of Rotation cut is too narrow and left if it is too
wide.
Step 22Tighten the motor mount bolts.
Step 23 – Remove the lockout/tagout.
Step 24 – Power on the ALS 4.0 and follow normal
startup (Section 3.1) and homing procedures and repeat
Steps 1-17.