Chapter 6 VT100 Terminal Emulation
Emulating a VT100 terminal
SmartClass E1 Tester User’s Guide 75
3 Verify that VT100 is selected for the RS232 DB9 port, if needed. See
“Specifying DB9 port usage” on page 21.
4 From the main menu, select VT100.
The VT100 menu appears.
The main menu displays help for using the menus: Press and hold the
*Action key and then press the appropriate key to view a menu.
5 Press and hold the *Action key and then press the 4 key to view the
Settings menu. Specify the following settings.
6 Press and hold the *Action key and then press the 5 key to view the File
menu and then select Connect.
7 If the VT100 session does not start after a few seconds, view the File
menu and then select 10 Spaces.
A VT100 session screen appears. The menu for the network element
appears after a few seconds.
8 To view different parts of the screen, use the arrow keys.
Parameter Option
Serial Speed Select a baud rate:
1200
2400
9600
19200
38400 (default)
57600
115200
Data Bits Select a data bit setting:
–7
8 (default)
Flow Control Specify the flow control:
Xon/Xoff
None (default)
Stop Bits Select a stop bits setting:
1 (default)
–2
Parity Select the parity:
None (default)
–Odd
–Even