Additional bypass features
Recall Last Bypass Recalls all zones that were bypassed the last time the bypass
zone feature was used.
Bypass All Open Zones Allows the user to quickly bypass all open zones with a single
command.
Clear Bypass Instantly clears all bypass conditions from the zones assigned
to the partition.
Programming a Bypass Group Use when you consistently bypass the same zones. This
feature allows you to store in memory one group of bypassed
zones per partition.
Activating a Bypass Group Loads a stored bypass group from memory.
Note: Ensure that no zones are unintentionally bypassed when arming the system.
Note: 24-hour zones can only be unbypassed manually.
Note: For security reasons, your installer has programmed the system to prevent you from
bypassing certain zones (e.g., smoke detectors). For more information on fire zones see “Fire
and CO Zone Types”.
Bypassing individual zones
To bypass individual zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag.
3. To bypass a zone, choose one of the following options:
- Enter a three digit zone number.
- Use the [<] [>] keys to scroll to the zone, and press [*].
4. Optional: To toggle or undo the bypassing of a zone, enter the three digit zone number, or
press [*].
5. To exit Bypassing mode, press [*].
If the system is ready to arm , the Ready indicator is on.
Bypassing all open zones
To bypass all open zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag.
3. Choose one of the following options:
- Press [9] [9] [8].
- Use the [<] [>] keys to scroll to Bypass Options, and press [*].
- Use the [<][>] keys to scroll to Bypass Open Zones, and press [*]
4. To exit Bypassing mode, press [*].
If the system is ready to arm , the Ready indicator is lit.
PowerSeries Pro HS3032/HS3128/HS3248 User Manual16