Recalling the last bypassed zones
To recall the last bypassed zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag to the keypad
reader.
3. Choose one of the following options:
- Press [9] [9] [9].
- Use the [<][>] keys to scroll to Bypass Options, and press [*].
- Use the [<][>] keys to scroll to Bypass Recall, and press [*]
4. To exit Bypassing mode, press [*].
If the system is ready to arm, the Ready indicator is on.
Clearing the bypass indication from all zones
To clear the Bypass Indication from all zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag to the keypad
reader.
3. Choose one of the following options:
- Press [0] [0] [0].
- Use the [<] [>] keys to scroll to Clear Bypasses, and press [*].
4. To exit Bypassing mode, press [*].
Bypass groups
Program frequently bypassed zones into the system as a bypass group. Using bypass groups avoids
individually bypassing each zone. One bypass group can be programmed per partition.
Note: This feature is not to be used in UL listed installations.
Programming a bypass group
To program a Bypass group, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code or present a proximity tag to the keypad
reader.
3. Choose one of the following options:
- Enter the three digit zone number of the zones you want to bypass.
- Scroll to the zone you want to bypass and press [*]
4. Choose one of the following options:
- To program the bypass group with the current bypassed zones, press [9] [9] [5].
17PowerSeries Pro HS3032/HS3128/HS3248 User Manual