4. Installation setting
JCX-161 BNWAS Installation Manual
89
7ZPNA4321
4.5.2 INPUT DATA function
This function is to display RS-422 input signal with character codes from external navigation
equipment, which is connected to the 6 contacts connector.
Receiving data from the serial ports can be displayed in the screen.
The serial ports and display formats (ASCII/BINARY) can be displayed.
The serial port which is an output setting cannot be displayed.
Operating procedure
1) Display the maintenance menu by referring “4.1 Changing to maintenance mode”.
2) Select sequentially “MAINTENANCE” and “INPUT DATA” with , and then press . After
that, the following screen is displayed.
3) Select a SIO[2] port with , and then press . After that, its receiving data is displayed in
the screen.
When
is pushed again, the display stops.
When change the display format, press
, and then the format of ASCII and BINARY
changes respectively.
When no data is displayed, check the connection and the setting of the serial port.
SIO[2] ASCII *
'ENT':START/STOP
'
▲▼
' :PORT
'<>' :ASCII/BINARY
Selected
display format
Operation
description
screen
Selected serial port
Select a SIO[2] port.