1. Specification
JCX-161 BNWAS Installation Manual
14
7ZPNA4321
1.8.4 Reset button unit (Waterproof) (NCJ-896)
1) Reset input function The membrane switch is used.
2) Alarm output function - Audible alarm
75 dB(A) to 85 dB(A) (both inclusive)
The buzzer sound level (High/Low) can be changed.
The buzzer continuous/intermittent sound can be
changed from NWZ-4650.
- Visual indication
Illuminated section of membrane switch provides
visual indication.
3) Setting - Dimmer (3 levels)
4) Waterproof spec. IP56
5) Power consumption 0.6 W
1.8.5 Buzzer unit (NVS-785)
1) Alarm output function - Audible alarm
75 dB(A) to 85 dB(A) (both inclusive)
The buzzer sound level (High/Low) can be changed.
The buzzer continuous/intermittent sound can be
changed from NWZ-4650.
2) Power consumption 0.4 W
3) Connected Number MAX. 23 units (MAX. 5 units / 1CH)