1. Specification
JCX-161 BNWAS Installation Manual
13
7ZPNA4321
1.8.2 LCD Display unit (NWZ-4650)
1) Serial communication - RS-485 Communication speed: 19.2 kbps
󲨘 for communication with NCK-175
- RS-422C Communication speed: 4.8 kbps
󲨘 for interface of external navigation equipment
2) Reset inputting function Pushbutton switch is used.
3) Alarm output function - Audible alarm
󲨘 None
- Visual indication
󲨘 Illumination of the LCD provides visual indication.
4) Setting - Backup officer selection / name
- Operational mode selection
- Time Interval
- Buzzer sound (continuous / intermittent)
󲨘 (for NCJ-895/896, NVS-785)
- Password change
- Contrast, Dimmer, click sound, back light color
- Buzzer connection ON/OFF
- RMS output ON/OFF
5) Max. connections 1 unit
6) Power consumption 4 W
1.8.3 Reset button unit (NCJ-895)
1) Reset input function The membrane switch is used.
2) Alarm output function - Audible alarm
75 dB(A) to 85 dB(A) (both inclusive)
The buzzer sound level (High/Low) can be changed.
The buzzer continuous/intermittent sound can be
changed from NWZ-4650.
- Visual indication
Illuminated section of membrane switch provides
visual indication.
3) Setting - Dimmer (3 levels)
4) Power consumption 0.6 W