1. Specification
JCX-161 BNWAS Installation Manual
3
7ZPNA4321
1.2 Features
1.2.1 Versatile functions with standard configuration
1) BNWAS function
When dormant period are measured, and the confirmation is not done, warning is
output with the visual indication and the alarms according to the sequence of 1.1.3.
2) Support of emergency call function and bridge alarm transfer function
The emergency call function is offered without optional equipment. The bridge alarm
can transfer an unacknowledged alarm with the serial interface that uses the
IEC61162-1 ALR sentence.
1.2.2 Various reset devices and number of inputs
1) Reset devices
A maximum of 6 pushbutton reset devices (NCJ-895 and NCJ-896) can be provided so
that the dormant period can be reset within 15 s in anywhere since the visual indication
starts. The reset function is equipped also in the LCD Display unit (NWZ-4650).
2) Motion sensor type reset device (option)
The motion sensor (NYG-5) which performs automatic reset by human presence and
motions can be installed.
3) Reset by external unit
The system supports the reset signal from other navigational equipment. The reset
signal can be input via. an IEC 61162 serial interface or a contact input.
1.2.3 Output to external device
1) System Failure output by contact signal
The system can output the System Failure to CAS by contact signal.
2) VDR output by serial interface
The system can output machine status or alarm situation to VDR by the serial interface
using the IEC61162-1 ALR sentence.