3. Wiring
JCX-161 BNWAS Installation Manual
51
7ZPNA4321
3.3.5 Reset button unit connection terminal block (CDJ-2486 TB2)
Outline of terminal block
Wiring table
Terminal No. Terminal name I/O Function Connected unit
1 RESET1 + O RESET1 power output +
2 RESET1 - - RESET1 power output -
3 RESET1 RS I RESET1 reset input
4 RESET1 VI O RESET1 visual alarm output
5 RESET1 BZ O RESET1 audible alarm output
Reset button unit (*1)
6 RESET2 + O RESET2 power output +
7 RESET2 - - RESET2 power output -
8 RESET2 RS I RESET2 reset input
9 RESET2 VI O RESET2 visual alarm output
10 RESET2 BZ O RESET2 audible alarm output
Reset button unit
External navigation
equipment (*2)
11 RESET3 + O RESET3 power output +
12 RESET3 - - RESET3 power output -
13 RESET3 RS I RESET3 reset input
14 RESET3 VI O RESET3 visual alarm output
15 RESET3 BZ O RESET3 audible alarm output
Reset button unit
External navigation
equipment (*2)
16 RESET4 + O RESET4 power output +
17 RESET4 - - RESET4 power output -
18 RESET4 RS I RESET4 reset input
19 RESET4 VI O RESET4 visual alarm output
20 RESET4 BZ O RESET4 audible alarm output
Reset button unit
External navigation
equipment (*2)
RESET1
125
RESET2 RESET3 RESET4 RESET5