3. Wiring
JCX-161 BNWAS Installation Manual
52
7ZPNA4321
Terminal No. Terminal name I/O Function Connected unit
21 RESET5 + O RESET5 power output +
22 RESET5 - - RESET5 power output -
23 RESET5 RS I RESET5 reset input
24 RESET5 VI O RESET5 visual alarm output
25 RESET5 BZ O RESET5 audible alarm output
Reset button unit
External navigation
equipment (*2)
*1. The Reset button unit connected to RESET1 has a function of an emergency call.
*2. Connect with the "-" terminal and a "RS" terminal.
Wiring method
Same as wiring method of Clause 3.3.4 CDJ-2486 TB1.