4. Installation setting
JCX-161 BNWAS Installation Manual
95
7ZPNA4321
4.7 SOFT UPDATE function
Software update of the display unit is performed with connecting to RS-232C terminal of an external
Personal Computer (PC) and operating the firmware update tool on the PC.
4.7.1 Updating
Software can be updated with connecting an external Personal Computer (PC).
When updating the software, a PC, a power supply/data cable, one set of PC software for the
update, and an update file are required.
Required time of updating software
Unit Required Time (Standard) Remarks
LCD Display unit NWZ-4650 Approx. 2 minutes On baud rate setting: 115200 bps
Confirmation procedure of software version
1) Press in order to indicate the main menu (normal mode).
2) Press long and for more than 3 seconds.
3) So the screen is changed to the maintenance menu (maintenance mode).
When it changes to maintenance mode, the [M] icon is indicated under the screen.
4. Select sequentially "MAINTENANCE", "SOFT VERSION", "DISPLAY VER" with .
BNWAS DISPLAY VER
FIRMWARE VER:
R01.00
SERIAL NO:
KF19372
BARCODE NO:
01234567890
[M]
The [M] icon is
displayed.
BNWAS EQUIPMENT
BUZZER CH
NMEA COMM
RMS OUTPUT
MAINTENANCE
MASTER RESET
SOFT UPDATE
[M]