3. Wiring
JCX-161 BNWAS Installation Manual
62
7ZPNA4321
3.5 Reset button unit (NCJ-895 TB1)
• Outline of terminal block
• Wiring table
Terminal
No.
Terminal
name
I/O Function Connected unit
1 +12V I Power supply input +
2 E - Power supply input -
3 RS O Reset output
4 VI I Visual alarm input
5 BZ I Audible alarm input
Control unit
1
5
BZ VI E +12VRS