1. Specification
JCX-161 BNWAS Installation Manual
10
7ZPNA4321
1.7 General specifications
1.7.1 IEC60945 environment specification
Operation temperature: -15 to 55°C
-25 to 55°C (NCJ-896 Reset button unit (Waterproof))
Relative humidity: 93% (at 40°C, without condensation)
Vibration: 2 to 13.2Hz amplitude ±1.0mm/ 13.2 to 100Hz acceleration 0.7m/s
2
1.7.2 Power supply
Normal power supply: 100 to 120V AC / 200 to 240V AC ±10%, 50/60Hz
Emergency power supply: 24V DC ±10%
Maximum power consumption: 23.0W (100V AC), 22.7W (220V AC), 20.5W (24V DC)
Note 1: Maximum electric power consumption depends on the system configuration.
Example composition: NCK-175 x1, NWZ-4650 x1, NCJ-895 x1, NCJ-896 x2,
NVS-785 x8
Power consumption: 13.0W (max)
100V AC 0.13A (max)
220V AC 0.06A (max)
24V DC 0.54A (max)
Note 2: Emergency power supply must have enough capacity to supply an electric power for 6
hours after main power supply stops.