4. Installation setting
JCX-161 BNWAS Installation Manual
86
7ZPNA4321
[Alarm number setting method]
Set the alarm number to correspond to the ALR (Set alarm state) sentence of IEC61162-1.
Alarm number (example): RA
300
$__ALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF>
[Character input method]
Select one desirable character with , and then press .
[C] deletes one character, [AC] deletes all characters, [OK] ends this edit, and [EXIT] cancels
this edit.
Also deletes one character.
When finished the edit, select [OK], and then press .
Then edited character string is reflected. When edit is canceled, select [EXIT], and then
press .
Alarm's description text
Alarm's acknowledge state ,A=acknowledged
V=unacknowledged
Alarm condition , A=threshold exceeded
V=not exceeded
Unique alarm number(identifier) at alarm source
Time of alarm condition change, UTC
Talker ID
BNWAS ALARM NO
ABCDEFGHIJKLMNOPQRSTU
VWXYZ. 0123456789[
\
]_
"#$%&'()?@+-*/^,:;<=>
! [C][AC][OK][EXIT]