ņ43
Procedure 1 Hold down [RADAR MENU] key.
The Code Input Menu will appear.
2 Press [0] key.
3 Move the cursor onto the “ENT” button
in the Code Input menu, and press
[ENT] key.
The Adjust Menu will appear.
4 Press [8] key while the Adjust Menu is
open.
The SP/TT INIT Setup Menu will appear.
5 Press [2] key.
The TT Menu will appear.
To change the quantization level of the automatic acquisition area
6 Press [2] key.
The numeric keypad for inputting the quantization level of the automatic acquisition area
opens.
7 Enter the Video TD Level value.
The multi-function control can also be used to enter the value.
After having entered the value, move the cursor onto the “ENT” button and press [ENT]
key.
The quantization level can be entered using the numeric keypad, or the multi-function
control knob.
When entry is complete, set the cursor over the "ENT" button on the numeric keypad, and
press [ENT].
You can set this value smaller to detect targets with weaker signals, but by doing so the
unit may pick up unwanted signals that can cause the display of targets to be unstable.
Setting this to a larger value can cause the unit to ignore weaker signals. Filtering out
unwanted signals can stabilize the display of targets, but targets with weaker signals can
be more difficult to detect.
To change the quantization level of tracking and manual acquisition
6 Press [3] key.
The numeric keypad for inputting the quantization level of tracking and manual
acquisition opens.
7 Enter the Video High Level value.
The multi-function control can also be used to enter the value.
After having entered the value, move the cursor onto the “ENT” button and press [ENT]
key.