ņ31
Use a shielded screw driver.
Touching the magnetron with metal (a tool) causes
performance deterioration.
Step 8: Connect the magnetron cable.
Connect the cables after fixing the magnetron.
Solder the cables to the pulse transformer pins.
Pass the magnetron cable through the protection tube (reused).
Step 9: Connect the magnetron cables as follows:
the green cable to No. 16 of the pulse transformer and
the yellow cable to No. 15 of the pulse transformer.
After soldering, place the cables into the bush and attach the cover.
Be careful not to connect cables faultily.
Bush
Y
ellow
Green