5-11 
5.1.4 Cursor Modes (Cursor)  
 
 
Types and Functions of Cursor Modes 
 
The types of cursor modes are listed in the table below.    To use the function of a cursor mode, move the cursor 
onto the PPI object and press the [ENT] key. 
 
Mode Function 
ACQ TT  Enables the target tracking function to acquire a target in manual mode. 
ACT AIS  Activates AIS targets, and sets a point filter. 
TGT Data  Displays the numeric data of a tracked target or AIS target. 
CNCL TT  Cancels a target tracking. 
DEACT AIS  Deactivates AIS target. 
CNCL Data  Hides the displayed numeric data of a tracked target or AIS target. 
Mark  Puts a temporary mark.     
Property  Displays the information of tracked targets, AIS targets, and marks. 
AUTO  Changes operation in accordance with the object at the cursor position. 
 
 
Change of Cursor Mode 
 
 
  Procedures    1  Move the cursor to the cursor mode    Cursor    (upper right of the display 
①  on page 2-19), and press the [ENT] key.    On the PPI, press the   
[CLR / INFO] key and select a desired cursor mode from the list. 
 
  The selected cursor mode will be shown at the cursor mode (upper right of the display on 
page 2-3). 
 
Note:
  If the function of a selected cursor mode is not used for one minute or more, the cursor mode is 
automatically changed to    AUTO .