EasyManuals Logo

JRC JMA-5912-6 User Manual

JRC JMA-5912-6
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #404 background imageLoading...
Page #404 background image
11-1
11.1 JMA-5912-6 TYPE RADAR
(1) Class of emission P0N
(2) Display Color Raster Scan
(3) Screen 23.1-inch Color LCD
Effective diameter of radar display, more than 320 mm
(4) Range Scale 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48, 96 NM
(5) Range Resolution Less than 30 m
(6) Minimum Detective Range Less than 40 m
(7) Range Accuracy Less than 1 % of the maximum distance of the range scale in
use or less than 15 m whichever is larger
(8) Bearing Accuracy Less than 1 °
(9) Bearing Indication Relative Motion mode: Head-up/Course-up/North-up
True Motion mode: Course-up/North-up
(10) Ambient Condition According to IEC60945-4
Temperature
Scanner: -25 to +55 ℃
(Storage Temperature: -25 to +70 ℃)
Other Unit except Scanner: -15 to +55 ℃
Relative Humidity
93 % at +40 ℃
Vibration
2 to 13.2 Hz, amplitude ±1 mm ±10 %
13.2 to 100 Hz, Gravity acceleration 7 m/s
2
Velocity of the wind 51.5 m/s (100knot)
(11) Power Supply Input +24 VDC (Display Unit)
+24 VDC (Scanner)
* Display Unit correspond to 100/110/115/220/230/240 VAC
when use NBA-5111.
(12) Power Consumption Approx. 140 W (typical)
Approx. 620 W (In maximum wind resistant velocity)
(13) Power Supply Voltage Fluctuation +24 VDC –10/+50 % (Display Unit)
+24 VDC –10/+50 % (Scanner Unit)
(14) Pre-heating Time Approx. Within 1 min 30 sec

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-5912-6 and is the answer not in the manual?

JRC JMA-5912-6 Specifications

General IconGeneral
BrandJRC
ModelJMA-5912-6
CategoryMarine Radar
LanguageEnglish

Related product manuals