7-29
[II] Transmission Monitor Adjustment (MON Indicator Adjustment)
Adjust the circuit for monitoring the transmission performance of the radar equipment.
Procedures 1. If the performance monitor is equipped with an inter-switch function,
set it as the master display unit.
2. Open the Serviceman Menu.
3. Open the MON (Performance Monitor) Indicator Adjustment menu by
performing the following menu operation.
1. Adjust Menu
→ 4. TXRX Adjustment
→ 5. MON Indicator Adjustment
4. Increase or decrease the adjustment value so that the performance
monitor level indicator will be adjusted to "8."
5. Press the Exit button to close the adjustment menu.
Note: During performance monitor adjustment, all acquisitions by the target tracking function are
released.
The released target acquisitions are not recovered.
Adjusted to 8