8-4 
8.2    Maintenance on each Unit
yyyy
yyyy
8 
 
z  If the radiator front face (radiation plane) is soiled with 
smoke, salt, dust, paint or birds’ droppings, wipe it 
with a piece of soft cloth wetted with alcohol or water 
and try to keep it clean at all times.  Otherwise, radar 
beam radiation may attenuate or reflect on it, resulting 
in deterioration of radar performance. 
z  Never use solvents of gasoline, benzine, 
trichloroethylene and ketone for cleaning. 
(1) Radiator 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Check up and clean the radiator. 
 
 
(2) Rotating section 
 
(a) Supply Oil Seal 
  An scanner unit with a grease nipple needs grease supply.    Remove the cap of the grease nipple 
on the front of the radiator support, and supply grease with a grease gun. 
  Make the oiling every six months.    The oil quantity shall be approximately 100 g, which is as 
much as the grease comes out of the oil seal.    Use the grease of Mobilux 2 of Mobil Oil. 
 
(b) Oiling gears 
  Apply grease evenly to the tooth surfaces of the main shaft drive gear and the encoder drive gear 
with a spreader or brush.    Oiling in short intervals is more effective to prevent the gears from 
wear and tear and extend their service life, but oil at least every six months. 
  Use Mobilux2 of Mobile Oil. 
 
(c) Mounting legs 
  Check the mounting legs and mounting bolts of the scanner unit case for corrosion at intervals 
and maintain them to prevent danger.    Apply paint to them once a half year because painting is 
the best measure against corrosion. 
Attention