Section 16 Setting up Screen View 16-58
16.2.19 Setting up the Water Depth display
When [Depth Graph] is selected on the classification pain, the [Depth Graph] dialog is shown on the
Edit pain.
The following table shows the setting details:
Setting item Description Setting values
Depth Range(Docking) Select a depth range for the docking depth
graph from the combo box.
AUTO, 10 m, 25 m, 50 m
Depth Range(Voyage) Select a depth range for the route depth graph
from the combo box.
AUTO, 50 m, 100 m, 250
m
Time Range Select a time range for the depth graph from
the combo box.
10 min, 15 min, 30 min,
60 min, 12 hours
Reference
Switch the reference of the water depth value.
AUTO: Switch the reference of the water
depth value according to the received
value.
Keel: Set the reference of the water depth to
keel.
Transducer: Set the reference of the water
depth to transducer. It can be selected
only when FURUNO is selected in
[Device Installation] - [Echo Sounder
1].
Surface: Set the reference of the water depth
to surface. It can be selected only
when FURUNO is selected in [Device
Installation] - [Echo Sounder 1].
AUTO, Keel,
Transducer(When
FURUNO is selected),
Surface(When FURUNO
is selected)