– 12 –
Connection of the power plug to the power depends on the specications of the product. Adjust the power
plug to the power specications to connect.
3-12.Connectingthepowerplug
 Incaseoftheproductofsingle-phase,200to240Vspecications(CEspecications):
Connect the sky-blue and brown wires of the power cord to the power terminal (AC200 to 240V) and the
yellow/green wire to the ground (earth) terminal respectively.
Incaseoftheproductof3-phase,200to240Vspecications:
Connect the red, white and black wires of the power cord to the power terminal (AC200 to 240V) and the
yellow/green wire to the ground (earth) terminal respectively.
Incaseoftheproductofsingle-phase,200to240Vspecications(otherthanCEspecications):
Connect the black and white wires of the power cord to the power terminal (AC 200 to 240V), and the
yellow/green wire to the ground (earth) terminal respectively.
CAUTION
:
Topreventpossibleaccidentscausedbyleakageordielectricstrength,anappropriatepowerplug
shallbeinstalledbyapersonwhohasanexpertknowledgeofelectricity.Besuretoconnectthe
powerplugtothereceptaclethatiswellgrounded.