– 25 –
①
Settingofthenumberofseams(level1)
The number of seams for activating the stacker is set.
The preset number of seams and the current seam are indicated.
④
Settingofthenumberofdelaystitchesforthethreadtrimmerpresser(level2)
The number of stitches to be sewn before the thread trimmer presser works after the material has come
out of the sensor is set.
②
SettingoftheNo.ofpcs.counter(level1)
The number of pieces of products to be sewn is set.
The No. of pcs. counter increments by one every time the stacker operates.
③
Settingofuse/disuseofthestacker(level1)
Whether the stacker is used or not is selected.
0 : Not used
1 : Used (The stacker is controlled when sewing the last seam.)
Setting range 0 to 99 stitches
5-5.Detailsofselectedfunctions
Currentseam(theordinalpositionoftheseambeingsewnwithrespectto
the set number of stitches is indicated)
Setvalue(settingrange1-9)
Setting range 0 to 9999
⑤
Settingofthenumberofdelaystitchesforthestackerpresser(level2)
The number of stitches to be sewn before the stacker presser works after the thread trimmer presser has
worked is set.
Setting range 0 to 999 stitches
⑥
Settingofthenumberofdelaystitchesforoperatingthestackerandstoppingthemachine(level1)
The number of stitches to be sewn before the sewing machine stops after the material has come out of
the sensor is set.
Setting range 0 to 999 stitches
⑦
Settingthedelaytimeforthestackerblow(level2)
The time to be elapsed before the stacker blow works after the stacker presser has worked is set.
Setting range 0 to 9900 ms