– 26 –
⑧
Settingthetimeforthestackerblow(level1)
The length of time during which the stacker blow works after the delay time for the stacker blow has
elapsed.
Setting range 0 to 9900 ms
⑩
Settingthespeedofstitchforthehigh-speedmode(level1)
The speed of stitch for the high-speed mode is set.
Setting range 200 to 8000 sti/min *
⑪
Settingthespeedofstitchforthelow-speedmode(level1)
The number of low-speed revolutions is set.
Setting range 200 to 8000 sti/min *
⑫
Settingthespeedofstitchforthecurvesensor(level1)
The speed of stitch for the section where the curve sensor is effective (from the number of stitches at
which the curve sensor starts to the one at which the sensor stops) is set.
Setting range 200 to 8000 sti/min *
⑬
Settingthespeedofstitchforproducingchain-offthread(level2)
The speed of stitch to be employed when operating the chain-off thread (starting) pedal.
Setting range 200 to 8000 sti/min *
⑭
Settingofthestartdelaytime(level2)
The time to be elapsed before starting the machine after the material has been detected is set.
Setting range 0 to 9900 ms
⑨
Settingthedelaytimeforliftingthethreadtrimmer(level2)
The time to elapsed before lifting the thread trimmer presser after the stacker blow has worked is set.
Setting range 0 to 200 ms
⑮
Settingofthenumberofdelaystitchesforstoppingthemachine(level1)
The number of stitches to be sewn before the machine stops after the normal-seam material (other than
the stack mode) has come out of the sensor is set.
Setting range 0 to 999 stitches
* "sti/min"isanabbreviationfor"stitchesperminute."