– 27 –
⑰
Curvemodesetting(level1)
Whether the curve sensor is used or not is selected.
0 : Not used
1 : Used
⑱
Curvedifferentialfeedmodesetting(level1)
Whether the differential feed mechanism is activated or not by means of the curve sensor is selected.
0 : Not used
1 : Used
⑲
Thenumberofstitchesforstartingthecurvemode(level1)
The number of stitches to be sewn before the curve mode or differential feed mode starts after the curve
sensor has detected a curved part of the material is set.
Setting range 0 to 999 stitches
⑳
Thenumberofstitchesforendingthecurvemode(level1)
The number of stitches to be sewn from the start to the end of the curve mode or differential feed mode
is set.
Setting range 0 to 999 stitches
Thenumberofstitchesforsuckingchain-offthreadatthebeginningofsewing(level2)
The number of stitches for sucking chain-off thread at the beginning of sewing is set.
Setting range 0 to 999 stitches
Curl blow output time (level 2)
The time to be elapsed before turning off the curl blow after the machine has stopped is set.
Setting range 0 to 60 seconds
Presser-footliftwaitingtime(level2)
The time to be elapsed before lifting the presser foot after the machine has stopped is set.
(The presser foot automatically goes up when the machine has stopped after stacking.)
Setting range 0 to 9900 ms
⑯
Settingofthestartmode(level2)
The start mode of the machine is set.
Either the automatic mode by the start sensor or the manual mode by the starting pedal is selected.
0 : Manual mode (The start sensor is inoperative.)
1 : Automatic mode
(The starting pedal is used as the chain-off thread switch.)