EasyManuals Logo

KAESER ASD T Series User Manual

KAESER ASD T Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Collect condensate in a suitable container and dispose of in accordance with environmental
regulations.
Further information The dimensional drawing in chapter 13.3 gives the size and position of the condensate drainage
connection ports.
6.5 Making the Power Supply Connection
This is a Tri-Voltage machine.
The machine can be set up to one of the following supply voltages:
208V
230V
460V
Precondition The power supply disconnecting device is switched off.
The disconnecting device is locked in the off position.
A check has been made to ensure no voltage is present.
1. Have the electrical connections carried out by authorized personnel only.
2. Carry out protection measures as stipulated in relevant regulations (IEC 364 or example) and in
national accident prevention regulations. In addition, the regulations of the local electricity supplier
must be observed.
3. In case of a fault, check the disconnecting time of the supply disconnecting device.
4. Use supply conductors and fuses in accordance with local regulations.
5. The user must provide the machine with a lockable supply disconnecting device.
This could be, for example, a switch-disconnector with fuses. If a circuit breaker is used it must
be suitable for the motor starting characteristics.
6. Check that the correct taps on the control voltage transformer are connected according to the
supply voltage.
If this is not correct, change the connection to suit the power supply voltage.
DANGER
Danger of fatal injury from electric shock!
Switch off and lock out the supply disconnecting device and check that no voltage is present.
7. If necessary: Set up the machine for the correct power supply voltage as described in chap‐
ter 6.5.1.
8. Connect the power supply.
Further information The electrical diagram 13.4 contains further specifications for electrical connection.
6.5.1 Changing main voltage connections
Machine set up for [V] 208 230 460
Machine may be modified
[V]
230 208 208
460 460 230
Tab. 36 Voltage selection
6 Installation
6.5 Making the Power Supply Connection
9_5721 06 USE
Service Manual Screw Compressor
ASD T Tri-Voltage
37

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASD T Series and is the answer not in the manual?

KAESER ASD T Series Specifications

General IconGeneral
ModelASD T Series
CategoryCompressor
Frequency50/60 Hz
Drive SystemDirect Drive
CoolingAir-cooled
TypeRotary Screw Compressor
Cooling SystemAir-cooled
Control SystemSigma Control 2
PressureUp to 15 bar
Integrated DryerYes
Voltage400 V
WeightVaries by model
Drive MotorIE3 Premium Efficiency