EasyManuals Logo

KAESER ASD T Series User Manual

KAESER ASD T Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Fan motor
Have the motor bearings checked by a KAESER Service representative.
10.9 Checking the Coupling
A defective coupling is recognizable by:
noisy running,
surface cracks,
color change.
WARNING
Danger of injury from rotating coupling!
Never switch the machine on without the safety screen in place over the coupling.
Fig. 28 Checking the coupling
1 Safety screen
2 Coupling
Check for uneven or noisy running
Precondition The machine is running
Check the coupling for noisy or uneven running
Make a visual check for damage
Precondition The power supply disconnecting device is switched off.
The disconnecting device is locked in the off position.
A check has been made that no voltage is present.
The machine has cooled down.
1. Remove the securing screws and take off the safety screen.
2. Turn the coupling by hand and look for damage or color change.
3. Refit the safety screen.
4. Close all access doors and replace all enclosure panels.
10 Maintenance
10.9 Checking the Coupling
68
Service Manual Screw Compressor
ASD T Tri-Voltage 9_5721 06 USE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASD T Series and is the answer not in the manual?

KAESER ASD T Series Specifications

General IconGeneral
ModelASD T Series
CategoryCompressor
Frequency50/60 Hz
Drive SystemDirect Drive
CoolingAir-cooled
TypeRotary Screw Compressor
Cooling SystemAir-cooled
Control SystemSigma Control 2
PressureUp to 15 bar
Integrated DryerYes
Voltage400 V
WeightVaries by model
Drive MotorIE3 Premium Efficiency