Fault Possible cause Remedy
Cooling oil leaking into the floor
pan.
Hose coupling or maintenance
hose still plugged into the quick-
release coupling on the oil sep‐
arator tank.
Remove coupling or mainte‐
nance hose.
Oil cooler leaking. Call authorized KAESER Serv‐
ice representative.
Leaking joints. Tighten joints.
Replace seals.
Cooling oil consumption too
high.
Unsuitable oil is being used. Use SIGMA FLUID cooling oil.
Oil separator cartridge split. Change the oil separator car‐
tridge.
Oil level in the oil separator tank
too high.
Drain off oil until the correct level
is reached.
Oil return line clogged. Check dirt trap in the return line.
Tab. 46 Other faults and actions
9 Fault Recognition and Rectification
9.4 Other Faults
9_5721 06 USE
Service Manual Screw Compressor
ASD T Tri-Voltage
59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASD T Series and is the answer not in the manual?

KAESER ASD T Series Specifications

General IconGeneral
ModelASD T Series
CategoryCompressor
Frequency50/60 Hz
Drive SystemDirect Drive
CoolingAir-cooled
TypeRotary Screw Compressor
Cooling SystemAir-cooled
Control SystemSigma Control 2
PressureUp to 15 bar
Integrated DryerYes
Voltage400 V
WeightVaries by model
Drive MotorIE3 Premium Efficiency