EasyManuals Logo

KAESER ASD T Series User Manual

KAESER ASD T Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Connecting the dryer transformer
Power for the refrigeration dryer (if one is present) is provided by a transformer. This is not required
for 460 V power supply.
Do only use terminal 0V–208V–230V (primary side of the transformer) for changing the main
voltage connection. Do not change the terminal 0V–460V. This terminal is readily wired.
1. Open the control cabinet and insert the jumpers in the terminal strip ---X31 in accordance with
the electrical diagram.
2. If necessary:
Open the left access door and connect the transformer in accordance with the electrical diagram.
6.6 Option T2
Refrigeration dryer: Connecting the transformer according to the
power supply.
The refrigeration dryer transformer has tappings for various power supply voltages.
1. Check that the correct connections are made for the supply voltage provided for the machine.
2. If necessary, re-connect the transformer to match the power supply voltage.
Further information The electrical diagram in chapter 13.4 contains further details of the power supply connection.
6.7 Options
6.7.1 Option H1
Anchoring the machine
Use appropriate fixing bolts to anchor the machine.
Further information Details of the fixing holes are contained in the dimensional drawing in chapter 13.3.
6 Installation
6.6 Refrigeration dryer: Connecting the transformer according to the power supply.
9_5721 06 USE
Service Manual Screw Compressor
ASD T Tri-Voltage
39
Option T2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASD T Series and is the answer not in the manual?

KAESER ASD T Series Specifications

General IconGeneral
ModelASD T Series
CategoryCompressor
Frequency50/60 Hz
Drive SystemDirect Drive
CoolingAir-cooled
TypeRotary Screw Compressor
Cooling SystemAir-cooled
Control SystemSigma Control 2
PressureUp to 15 bar
Integrated DryerYes
Voltage400 V
WeightVaries by model
Drive MotorIE3 Premium Efficiency