Load management program
52 / 156
Shows the state of the current Charging Session.
Display values:
Not plugged in:
No electric vehicle is connected to the Wallbox.
Standby:
The vehicle is connected, but on standby.
Charging:
The vehicle is charging or in a charging pause and the vehicle is not
blocked.
Blocked:
The vehicle has been blocked by the Wallbox or no active charging
transaction exists.
Error:
The socket is degraded or fatal.
Point in time when the Charging Session has started.
Planned end of charging as communicated by the Electric Vehicle during
charge parameter discovery.
Describes whether the Charging Session is a Mode 3 charging session or
a high-level charging session.
Display values:
Basic signalling:
Mode 3 charging according to IEC 61851-1 controlled by basic signal-
ling.
ISO 15118:
Charging session controlled by high-level communication.
The maximum number of phases which a Electric Vehicle can use during
the charging transaction. Must be 1 or 3.
Current offered at the Wallbox (taken from charging profile or the preas-
signed current, whichever applies).
Current according to the last measurement at the Wallbox.
Energy requested by the electric vehicle during the last charge parameter
negotiation. Empty for charging controlled by basic signalling.
Energy consumed during the Charging Session.
Shows the state of the selected Wallbox.
Display values:
Free:
No vehicle is connected.
Not ready to charge:
The Wallbox is operational and the power switch is open.
Offering energy: