X8 MIG WELDER 2.4 Installation
i) Connect the cooling water hoses to the slot.
j) Close and lock the cable cabinet door.
Note:
When connecting the cables to the wire feeder, route the cables neatly so that the
cable cabinet door closes properly.
2.
Connect the interconnection cable to the power source.
a) Connect the welding current cable to the plus (+) side connector (1) on the power source.
The interconnection cable crosses from the wire feeder to the power source connector
diagonally.
Note:
If two wire feeders are connected to a power source, connect the interconnection
cable upright: from the wire feeder on the left to the connector (1) on the left.
b) Connect the earth return cable to the minus (-) side connector (2).
c) Connect the measurement cable to the measurement cable connector (4).
d) Connect the control cable to the control cable connector (3) on the same side as the
measurement cable.
e) If the water cooler is present, use the red connector (5) for the hose that goes to the
cooler.
OPERATING MANUAL | EN 53
©
KEMPPI 2017 | 1817