Keysight U1251B and U1252B User’s and Service Guide 7
Measurement Category 
The Keysight U1251B and U1252B Handheld Digital Multimeter has a safety 
rating of CAT III 1000 V/ CAT IV 600 V.
Measurement CAT I  are measurements performed on circuits which are not 
directly connected to the AC mains. For example, measurements on circuits not 
derived from the AC mains or specially protected (internal) mains-derived circuits.
Measurement CAT II  are measurements performed on circuits that are directly 
connected to a low voltage installation. For example, measurements on 
household appliances, portable tools and other similar equipment.
Measurement CAT III  are measurements performed on building installations. 
For example, measurements on distribution boards, circuit-breakers, wiring 
(including cables), bus-bars, junction boxes, switches, socket outlets within the 
fixed installation, equipment for industrial use and equipment that is permanently 
connected to the fixed installation such as stationary motors.
Measurement CAT IV  are measurements performed at the source of the 
low-voltage installation. For example, measurements on electricity meters, 
primary over-current protection devices and ripple control units.