6-18 Remote Control PLZ-U
Querying the channels that can be used
INST:CAT
Queries the channel number that can be used.
Query command: INSTrument:CATalog?
INST:CAT:FULL
Queries the channel number and ID that can be used.
Query command: INSTrument:CATalog:FULL?
Returns the current setting in response to INST:CAT:FULL?.
Example) When channels 1 and 3 can be used
Returns CH1,1,CH3,3.
Selecting the channel whose settings are to be displayed
INST:FOC
Selects the channel whose settings are to be displayed. Or, queries the current set-
ting.
Set command: INSTrument:[SELect]:FOCus
{CH1|CH2|CH3|CH4|CH5}
Query command: command:INSTrument:[SELect]:FOCus?
6.5.3 Measurement Commands
MEAS:CURR
Reads the measured current.
Query command: MEASure[:SCALar]:CURRent[:DC]?
MEAS:POW
Reads the measured power.
Query command: MEASure[:SCALar]:POWer[:DC]?
MEAS:VOLT
Reads the measured voltage.
Query command: MEASure[:SCALar]:VOLTage[:DC]?
MEAS:ETIM
Reads the elapsed time of measurement.
Query command: MEASure:ETIMe?

Table of Contents

Other manuals for Kikusui PLZ-U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kikusui PLZ-U Series and is the answer not in the manual?

Kikusui PLZ-U Series Specifications

General IconGeneral
BrandKikusui
ModelPLZ-U Series
CategoryControl Unit
LanguageEnglish

Related product manuals