6-26 Remote Control PLZ-U
6.5.6 Switching Function Commands
Executes sequentially the multiple load currents that are specified in CC or CR mode.
PULS
Turns on/off the switching mode. Or, queries the current setting.
Set command: [SOURce:]PULSe[:STATe] {OFF|ON|0|1}
Query command: [SOURce:]PULSe[:STATe]?
• Program data
Value OFF(0) Switching mode off
ON(1) Switching mode on
PULS:DCYC
Sets the switching duty cycle. Or, queries the current setting.
Set command: [SOURce:]PULSe:DCYCle <value>
Query command: [SOURce:]PULSe:DCYCle?
• Program data
Value 2 to 98
Resolution 0.1
Unit PCT
PULS:FREQ
Sets the switching frequency. Or, queries the current setting.
Set command: [SOURce:]PULSe:FREQuency <value>
Query command: [SOURce:]PULSe:FREQuency?
• Program data
Value 1 to 20 k
Resolution 1 to 1 K: 1
to 10 K:10
to 20 k: 100
Unit HZ
Sets the switching level
PULS:LEV:COND
Sets the level for CR mode. Or, queries the current setting.
Set command: [SOURce:]PULSe:LEVel[:VALue]
:CONDuctance <conductance>
Query command: [SOURce:]PULSe:LEVel[:VALue]
:CONDuctance?
PULS:LEV:CURR
Sets the level for CC mode. Or, queries the current setting.
Set command: [SOURce:]PULSe:LEVel[:VALue]
:CURRent <current>
Query command: [SOURce:]PULSe:LEVel[:VALue]
:CURRent?