69
69
FV20 support 50 kinds of protection alarm and can
record the latest three fault code (d1.00, d1.05,
d1.06) and bus voltage, current, operation
frequency and operation status of the latest fault.
Fault record 1 is the latest fault record.
See Chapter 7 of failure and alarm information
during failures recently occurred for the ease of
Trouble Shooting and repair.
6.21 Group d2
d2.00 Serial number
0~FFFF【100】
d2.01 Software version number
0.00~99.99【1.00】
d2.02 Custom-made version
0~9999【0
number
This group of parameters can’t be changed by user.
d2.03 Load type selection
0~9【0】
0: Heavy load G.
1: Light load L, such as fan.
2: Serging type B, such as lift.
3: 2-phase output type S.
4~9: Reserved.
d2.04 Rated capacity
Output power 0~999.9KVA
(Factory setting
d2.05 Rated voltage
0~999V(Factory setting)
d2.06 Rated current
0~999.9A(Factory setting)