460 F (238 C) (Grade 220)
490 F (254 C) (Grade 320)
509 F (265 C) (Grade 460)
Flash Point (typical): 450 F (232 C) (Grade 32)
460 F (238 C) (Grade 46)
470 F (243 C) (Grade 68)
515 F (268 C) (Grade 100)
530 F (277 C) (Grade 150)
545 F (285 C) (Grade 220)
580 F (304 C) (Grade 320)
585 F (307 C) (Grade 460)
Method: COC
Autoignition: Not Available
Flammable limits in Air, % by Volume
LEL: Undetermined
UEL: Undetermined
Extinguishing Media
Water Spray, Foam, Dry Chemical, CO2.
Fire Fighting Instructions
Water or foam may cause frothing. Use water to keep fire-exposed
containers cool. Water may be used to flush spills away from
exposures.
Products of combustion may contain carbon monoxide, carbon dioxide,
and other toxic materials. Do not enter enclosed or confined space
without proper protective equipment including respiratory protection.
---------------------------------------------------------------------------
6. ACCIDENTAL RELEASE MEASURES
---------------------------------------------------------------------------
Safeguards (Personnel)
NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections
before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE
EQUIPMENT during clean-up.
Remove source of heat, sparks, and flame.
Initial Containment
Dike spill. Prevent material from entering sewers, waterways, or
low areas.
Spill Clean Up
Recover free liquid for reuse or reclamation. Soak up with sawdust,
sand, oil dry or other absorbent material.
---------------------------------------------------------------------------
7. HANDLING AND STORAGE
---------------------------------------------------------------------------
Handling (Personnel)
Avoid breathing vapors or mist. Avoid contact with eyes. Avoid
prolonged or repeated contact with skin. Wash thoroughly after
handling. Wash contaminated clothing prior to reuse.
Handling (Physical Aspects)
Close container after each use. Do not pressurize, cut, weld, braze,
solder, grind, or drill on or near full or empty container. Empty
container retains residue (liquid and/or vapor) and may explode in