heat of a fire.
Storage
Store in accordance with National Fire Protection Association
recommendations. Store in a cool, dry, well-ventilated place. Store
away from oxidizers, heat, sparks and flames.
---------------------------------------------------------------------------
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
---------------------------------------------------------------------------
Engineering Controls
VENTILATION
Normal shop ventilation.
Personal Protective Equipment
RESPIRATORY PROTECTION
None normally required except in emergencies or when conditions
cause excessive airborne levels of mists or vapors. Select
appropriate NIOSH-approved respiratory protective equipment when
exposed to sprays or mists. Proper respirator selection should be
determined by adequately trained personnel and based on the
contaminant(s), the degree of potential exposure, and published
respirator protection factors.
PROTECTIVE GLOVES
Should be worn when the potential exists for prolonged or repeated
skin contact. NBR or neoprene recommended.
EYE PROTECTION
Safety glasses with side shields.
OTHER PROTECTIVE EQUIPMENT
Coveralls with long sleeves if splashing is probable.

Applicable Exposure Limits
If oil mist is generated, exposure limits apply.
PEL (OSHA): 5 mg/m3, 8 Hr. TWA
TLV (ACGIH): 5 mg/m3, 8 Hr. TWA, STEL 10 mg/m3
---------------------------------------------------------------------------
# 9. PHYSICAL AND CHEMICAL PROPERTIES
---------------------------------------------------------------------------
Physical Data
Appearance: Clear and bright
Odor: Mild petroleum hydrocarbon
Boiling Point: Not Available
Vapor Pressure: Nil
Vapor Density: >1 (Air=1.0)
% Volatiles: Nil
Evaporation Rate: Nil
Solubility in Water: Insoluble
Specific Gravity: 0.85-0.90 @ 60 F (16 C)
Pounds Per Gallon: 7.1-7.5 @ 60 F (16 C)

Viscosity (typical): cSt @ 40 C cSt @ 100 C
ISO 32 32.5 5.4
ISO 46 45 6.7
ISO 68 68.2 8.77
ISO 100 101.1 11.3
ISO 150 149 14.6
KMT 20418732